Product Categories

About Us

cable, vdsl, patch

 

Siemon Cat 7 Cables- T7F-01-1- TERA® 4 Pair Outlet- Siemon Cat 7 Cords- Cat 7 Cables- Cat 7 Cords- Tera Category 7a Structured Network Cabling

Live Support by Citricle


TERA® Category 7A Structured Network Cabling

TERA® 4-Pair Outlet

Part Numbers

T7F-01-1 TERA 4-pair outlet with black door, icon and boot
TERA outlets are the industry’s highest performing network cabling connectors. Outlets accept 1-, 2- and 4-pair plugs and terminate fully shielded category 7/class F cables. TERA outlets can be used in both the work area and in the telecommunications room.

TERA outlets are the industry’s highest performing network cabling connectors. Outlets accept 1-, 2- and 4-pair plugs and terminate fully shielded category 7/class F cables. TERA outlets can be used in both the work area and in the telecommunications room.

TERA®-MAX® Adapters for CT Faceplates

TERA® 1200 MHz Cable - International

TERA® 1000 MHz Cable - International

TERA® Patch Cords


Siemon’s TERA copper trunking cable assemblies provide an efficient and cost effective alternative to individual field-terminated components. Combining factory terminated and tested TERA outlets and fully shielded Siemon category 7A TERA cable, Siemon TERA trunking cable assemblies offer industry leading performance to 10 Gb/s and beyond. Standard configurations also help maintain consistent cable layout, facilitate efficient moves, adds and changes and significantly reduce scrap versus typical field installation. Major Product Features: 6-leg, double ended construction Presents a smaller profile when pulling Straight cut Allows left, right or center exit Terminated with TERA outlets Unique closed mesh sheath Ensures snag-free handling Material properties match the cable jacket Robust breakout kit Maintains cable orientation and prevents crossing Pre-attached pulling eye to aid installation Each leg is labeled for proper module orientation Utilizes high quality category 7A S/FTP Siemon cable Utilizes TERA outlets, factory terminated and tested for performance to 10 Gb/s and beyond Six-leg, double-ended design presents a smaller profile when pulling Unique breakout kit creates optimal cable orientation and limits cable crossing High-strength closed mesh sheath ensures snag-free handling Each cable assembly is coded with a unique identification number for administrative purposes
TERA-MAX patch panels provide outstanding performance and reliability in a shielded, high-density modular solution. As outlets are snapped into place, resilient ground tabs assure that each outlet is properly grounded for maximum protection from outside interference. No secondary outlet grounding operations are required, reducing overall installation time. High Density – 24 ports in 1U Port Identification - Bold port numbering enables quick identification of outlets Durable – Lightweight, high strength steel with black or metallic finish Angled TERA-MAX – Allows direct routing of cables to vertical managers, eliminating the need for horizontal cable managers
Siemon offers multiple CT adapter options for TERA and UTP MAX outlets to extend use of CT faceplates and other CT accessories beyond the use of CT couplers. Siemon`s new angled CT adapter allows TERA and MAX outlets to be mounted in CT faceplates and other accessories with CT openings. The adapter provides an angled work area mounting solution while using flat outlets, particularly useful in TERA applications. By orienting the outlets at an angle, it also reduces the mounting depth requirements to overcome shallow back boxes and other application challenges. Siemon`s new horizontal angled CT adapter allows TERA and MAX outlets to be mounted in CT faceplates and other accessories with CT openings. By orienting the outlets at an angle, this adapter reduces the mounting depth requirements to overcome shallow back boxes and other application challenges. This solution is particularly useful when using TERA in modular furniture or raceway installations where the cable is run horizontally. Note: Not compatible with screened MAX modules. Part of the TERA cabling system.

TERA® 1200 MHz Cable - International

Siemon’s TERA 1200 MHz cable perfectly complements the performance of our TERA outlets. Siemon cable exceeds all TIA/EIA and ISO/IEC requirements for ISO/IEC 15018 Broadcast Communications Technologies (BCT) and ISO/IEC 11801:2002 category 7/class F transmission performance. Utilizing Siemon cable is the ideal way to ensure optimum channel performance and is essential for a complete end-to-end warranted system. Pairs individually shielded with foil Sequential measurement markings on jacket Overall braid screen LS0H jacket Cable Construction S/FTP 0.64mm (0.025 in.) (22 AWG) solid bare copper 8.4mm (0.33 in.) max jacket diameter Pairs individually shielded with aluminum-polyester foil Overall tinned-copper braid Compliance ISO/IEC 11801:2002 category 7/class F ISO/IEC 15018 BCT Channel Application IEC 61156-7:2003 IEC 61156-5:2002 (Category 7) LS0H: IEC 60332-1, IEC 60754, and IEC 61034

TERA® 1000 MHz Cable - International

Siemon’s TERA 1000 MHz cable perfectly complements the performance of our TERA outlets. Siemon cable exceeds all TIA/EIA and ISO/IEC requirements for category 7/class F transmission performance. Utilizing Siemon cable is the ideal way to ensure optimum channel performance and is essential for a complete end-to-end warranted system. Pairs individually shielded with foil Sequential measurement markings on jacket Overall braid screen LS0H jacket Cable Construction S/FTP 0.57mm (0.023 in.) (23 AWG) solid bare copper 8.4mm (0.33 in.) max jacket diameter Pairs individually shielded with aluminum-polyester foil Overall tinned-copper braid Compliance ISO/IEC 11801:2002 (category 7) IEC 61156-5:2002 (Including transfer impedance and coupling attenuation) LS0H: IEC 60332-1, IEC 60754, and IEC 61034

TERA® Patch Cords

Part of the TERA cabling solution, TERA-to-TERA patch cords deliver twice the bandwidth of category 7A/class FA specifications when combined with the TERA outlet. TERA delivers up to 1.2 GHz of bandwidth per pair, providing the extra bandwidth critical for demanding applications like Broadband Video, with an upper frequency requirement of 862 MHz. Facilitated by 1- and 2-pair patch cords, TERA’s extended performance also supports cable sharing — the simultaneous convergence of video, voice and data onto a single 4-pair cable and outlet. 4-pair TERA-to-TERA supports category 7A/class FA performance to 10Gb/s and beyond Standard compliant interface — recognized within ISO/IEC 11801 Ed. 2.0 2-pair TERA-to-screened category 5e MC modular plug for 10/100 Ethernet, VoIP and video over IP 4-pair TERA-to-screened augmented category 6A MC modular plug for 1G/10G Ethernet performance 1-pair TERA-to-TERA for analog voice and video patching. Video balun cord also available 1-pair TERA-to-RJ11 for analog voice
TERA outlets are the industry’s highest performing network cabling connectors. Outlets accept 1-, 2- and 4-pair plugs and terminate fully shielded category 7/class F cables. TERA outlets can be used in both the work area and in the telecommunications room.
The TERA cable preparation tool uses a patent pending process to significantly reduce the time required to prepare fully shielded (S/FTP) cable. The tool includes an insert die with a blade, which is specifically designed to accurately strip the jacket and foil from 4-pair fully shielded cable without damaging the conductors. A template is also included to pre-align cable pairs and ensure proper pair positioning during termination.
TERA® 600 MHz F/FTP Cable - International
Siemon’s TERA 600 MHz F/FTP cable perfectly complements the performance of our TERA outlets. Siemon cable exceeds all TIA/EIA and ISO/IEC requirements for category 7/class F transmission performance. Utilizing Siemon cable is the ideal way to ensure optimum channel performance and is essential for a complete end-to-end warranted system. The TERA 600 MHz F/FTP cable is compatible with TERA outlets. Pairs individually shielded with foil Sequential measurement markings on jacket Overall aluminum/polyester foil LS0H jacket Cable Construction F/FTP 0.57mm (0.023 in.) solid bare copper 8.4mm (0.33 in.) max jacket diameter Pairs individually shielded with aluminum-polyester foil Overall aluminum/polyester foil tape Compliance ISO/IEC 11801:2002 category 7 IEC 61156-5:2002 category 7 LS0H: IEC 60332-1, IEC 60754, and IEC 61034
TERA® Video Patch Cord
TERA CATV baluns provide the optimum solution for the transmission of TV or CATV signals over structured cabling systems that were historically limited to voice and data transmission. These products convert the unbalanced TV signals designed for coaxial cabling (75 Ohm impedance) to balanced signals (100 Ohm impedance) as required for transmission over twisted pair (balanced) cabling. The TERA CATV adapters are specified and useable to 862 MHz. The 1-pair TERA to PAL and TERA to F-Type patch cords utilize an integrated balun. The 1-pair shielded TERA to shielded RJ45 patch cord allows connection to third-party RJ45 baluns. One cord used on each end of the video channel Minimizes cabling material and labor costs by consolidating applications on a single cable Only occupies a single pair in a TERA system to allow cable sharing Enables video transmission over structured cabling PAL or F-Type connector (IEC 60169-24) with integrated balun to interface with common video equipment

Click here for our Full Listing Suggested Siemon Price List - CALL FOR DISCOUNTS!! (866) 650-DATA Or East Coast Sales (866) 650-3282

Call American Tele Data At (866) 650-DATA
East Coast Sales: (866) 650-3282

 

 

 


TERA S/FTP Trunking Cable Assemblies
TERA®-MAX® Angled Faceplate Adapter
TERA-MAX Patch Panels
TERA® 1000 MHz Cable - International
TERA® 1200 MHz Cable - International
TERA® 600 MHz F/FTP Cable - International
TERA® Patch Cords
TERA® Video Patch Cord
TERA® 4-Pair Outlet
TERA® Cable Preparation Tool

 

 

 

BIF-Bend Insensitive Fiber

New Bend Insensitive Fiber Jumpers

Raceway Systems- Cable Tray